WHAT'S NEW?

Copyright Registration
We are happy to announce that we have been granted Copyright Registration for this website with effect from 07.08.2025. Registration Certificate


...


Webinar Videos Available!
The 10th Webinar from our "Successful Redevelopment" Series was conducted on 20.07.2025 and was followed by a long Q&A session!

Missed it? No worries!

You can now watch our Webinars here:
1. Overview - Structured Approach & Website: https://youtu.be/QvreZL1beuI?si=z8FKW6cuNG9fiHs0 ...


Regular Users
Login/ Sign in for free access to our Guideposts, Standards and Dos & Don’ts.
Structural Audit >> Non-destructive Testing

Non-destructive Testing

Non-destructive Testing (NDT) may be undertaken depending on the structural condition of the building. Following is a list of NDT, which are commonly undertaken for RCC buildings and what they indicate:

1. Ultrasonic Pulse Velocity Test … Integrity/ Denseness of Concrete

2. Rebound Hammer Test … Surface Hardness of Concrete

3. Half Cell Potential Test … Probability of Corrosion

4. Carbonation Test … Depth of Carbonation of Concrete

5. Core Test … Compressive Strength of Concrete

6. Chemical Analysis … Chloride (Corrosion of Rebars), Sulphate (Deterioration of Concrete), pH (Alkalinity of Concrete)

7. Cement Aggregate Ratio … Indicative of Concrete Mix


However, which tests should be undertaken for a particular RCC structure and the no. of its testing points should be decided by the Consultant (Auditor).